Select Committee on the Crossrail Bill Minutes of Evidence


Examination of Witnesses (Questions 3300 - 3319)

  3300. LORD YOUNG OF NORWOOD GREEN: I am trying to get my head round your survey as being described as a "second gear estate agent's survey"! Presumably Alan Baxter, the expert you rely on, said that the survey you have conducted was suitable and appropriate in the circumstances; but some of the things that appear to have been missed, even if we put to one side the internal surveys, there were comments that were made about the height of buildings and whether there were attics or not?
  (Mr Berryman) First of all, I would not accept the comment about the height of the building. That is not quite true, I accept the comment that the building is the height stated; but the crucial thing for us is the height of the masonry, not the height of the building overall. On the scale plan that was shown, although I am happy to accept the building is well over 15 metres tall, the masonry is about ten metres tall.

  3301. MR MOULD: Has that dealt with your Lordship's point? I was going to ask Mr Berryman if he could take this particular aspect a little further.

  3302. LORD YOUNG OF NORWOOD GREEN: The point I have been trying to make is about the quality of this survey; because the generic allegation being made is, quite frankly, that they are substandard and do not really meet the undertaking. You have part answered it by saying you are going to come back and do a more detailed survey; but I still worry a little bit that you have based assumption on this. What I want to be sure about, and probably my colleagues do as well, is the quality of this. Does the survey you have conducted meet the requirements at this point in your operation?
  (Mr Berryman) My Lord, I can only reiterate the point I made earlier that Alan Baxter is without doubt the leading expert in the country on this matter. I think the Petitioner alluded to that point in his evidence and expressed relief that we had employed Alan Baxter. All I can say is I rely heavily on his advice, and this is his advice, that this is the level of survey that is appropriate for this stage of the works.

  3303. BARONESS FOOKES: Would there be confusion over the stages, in that case? This is not the final stage—it is an interim stage and is appropriate for that stage, with more detailed surveys coming later?
  (Mr Berryman) Absolutely right, my Lady; I could not have put it any better.

  3304. MR MOULD: Mr Berryman, I wonder if we can illustrate this a little more with reference to one of the examples. You will recall that Mr Wheeler spent a little time dealing with 17-25 Wilkes Street, and that is on the screen in front of us now. This is the Alan Baxter Associates historic buildings and features aspect of the Phase 3 report. The height there you see at the top of the page is expressed as three storeys, plus cellars, plus weavers' attics to numbers 19, 23 and 25?
  (Mr Berryman) Yes, I see that.

  3305. If we could just turn on to page 14, this rather attractive drawing of the frontage of one those properties, do you see that?[33]

  (Mr Berryman) Yes.

  3306. We can see the three storeys there, can we, to parapet height?
  (Mr Berryman) Yes.

  3307. Then the attic structure on top?
  (Mr Berryman) Yes.

  3308. And the cellars we can see shown in outline below?
  (Mr Berryman) Yes.

  3309. If we then come back, please, to page 11 and we see the engineering aspect, we have moved away now from Mr Baxter and we have now come on to Mott MacDonald, have we not?[34]

  (Mr Berryman) That is correct.

  3310. We see the approach they have taken; in the general description of the property they say "three story brickwork terrace with basement and loft conversion", and we have seen that in the drawing we have just looked at?
  (Mr Berryman) Yes.

  3311. "The structure is approximately" and then various dimensions are given and the height is given as ten metres. What is the significance of the reference to "the structure"? Why is that important?
  (Mr Berryman) As Professor Mair explained during his presentation, the movement a building experiences is expressed as "strain".[35] If you imagine a tall building which is subject to a hogging bending moment so that it tends to do that (indicating), the taller the building the more the strain, so the height of the masonry elements is important in assessing what the strain will be at the top of the building. Similarly when a building is in a trough and doing that (indicating) the height is also important because it is the dimension from there (indicating) to there (indicating) which sets how big that strain will be.

  3312. You referred I think to "hogging". Just so I am clear, to the lay person is that the same thing as tensile strain?
  (Mr Berryman) Hogging is bending that way (indicating), and sagging is bending that way (indicating). It is hard to explain without a ruler.

  3313. LORD YOUNG OF NORWOOD GREEN: Convex and concave.
  (Mr Berryman) Convex and concave. Thank you, my Lord.

  3314. MR MOULD: Where does the concept of tensile strain come in?
  (Mr Berryman) Tensile strain comes in at the top of a hogging or a convex bending. The top of the building will be under tensile strain in that situation.

  3315. If we go down the page we have the general description. You have commented on the significance of the reference to the masonry structure, and then we come down to the building response findings; maximum settlement which Mr Wheeler referred to, 26mm in this case; maximum ground slope; and then maximum tensile strain and we see a percentage figure is given there?
  (Mr Berryman) Yes.

  3316. When we look at the classification of damage table we can see that it is expressed by reference to limiting tensile strains?
  (Mr Berryman) That is right.

  3317. Can you help the Committee with why the classification of damage table is expressed by reference to that consideration?
  (Mr Berryman) The damage to elements of a building, particularly a masonry structure but actually buildings in general, is almost always a result of tensile stresses developing. Those tensile stresses are as a result of tensile strains. The fact that the bricks try to move apart at the top of the building is a strain, but that puts a stress on the masonry structure. I am an engineer and it is hard to explain without doing sketches, I am afraid. That puts a stress on the structure. It is those stresses which lead to cracks in the buildings. Those cracks are almost always what cause any kind of damage, whether it is to the external features or the internal features of a building. Things like stucco plaster and so on, which have been referred to previously, if the building itself cracks they would tend to crack as well.

  3318. We can see that in the case of this building in relation to that factor, that is to say tensile strain, the classification of damage based on the engineer's assessment having regard to Mr Baxter's historic buildings assessment, is within the negligible category?
  (Mr Berryman) It is. I think you can see the negligible category goes up to 0.05 per cent strain. The strain in this building is 0.024 per cent, which is about half the limiting tensile strains. I just want to emphasise, as Professor Mair said, that these assumptions are very, very conservative. They are more than double the actual results which have been achieved, for example, on the Channel Tunnel rail link. We would expect this to be very much an upper bound of the potential strain that may result. I would forecast it would probably be about half that in reality.

  3319. LORD YOUNG OF NORWOOD GREEN: For that type of building?
  (Mr Berryman) The type of building does not make any difference, my Lord. The strain that is developed is a function of the ground movement and the way the ground moves.



33   Committee Ref: A19, Scale drawing of 21 Wilkes Street, London E1 (TOWHLB-20_05-014) Back

34   Committee Ref: A19, 17-25 Wilkes Street, Listed Building Assessments, General Description, Mott MacDonald (TOWHLB-20_05-011) Back

35   Crossrail Ref: P6, Assessment-Deformation Types, Professor Robert Mair, 20 February 2008 (LINEWD-RJM01-036) Back


 
previous page contents next page

House of Lords home page Parliament home page House of Commons home page search page enquiries index

© Parliamentary copyright 2008